Masters Theses

Date of Award

3-1925

Degree Type

Thesis

Degree Name

Master of Science

Major

Chemistry

Abstract

Summary and Conclusions:

1 We have shown that the picric acid methods are not accurate.

2. We have shown that the titrimetric methods are not adapted to clinical use.

3. We have demonstrated that the Folin-Wu method, which gives the same results

as the titrimetric methods, and is the most accurate method used in clinics,

gives results approximately 15 per cent too high, because of interfering

substances.

4. We have developed a mercuric nitrate method, specific for blood sugar by

virtue of the fact that it precipitates interfering substances before making the

determination.

5. We have developed an acetone method, specific for blood sugar, which gives

the same results as the mercuric nitrate method.

6. We have adapted our mercuric nitrate method and acetone method for

determining glucose in tissue extracts.

Files over 3MB may be slow to open. For best results, right-click and select "save as..."

Included in

Chemistry Commons

Share

COinS