Abstract
A methodology for determining nuclear power plant limited conditions for operation using risk assessment techniques is developed. The analysis of an emergency core cooling system of a pressurized water reactor demonstrates the methodology and shows that the methodology has a practical application in the area of nuclear plant operation. The results provide quantitative support for plant limited conditions for operation which are consistent with respect to risk.
Recommended Citation
Linn, Mark A., "Evaluation of the adequacy of the operating limits of nuclear electric power facilities through calculations of system dependability. " Master's Thesis, University of Tennessee, 1982.
https://trace.tennessee.edu/utk_gradthes/15041