Masters Theses

Date of Award

6-1985

Degree Type

Thesis

Degree Name

Master of Science

Major

Chemical Engineering

Major Professor

Donald W. Bouldin

Committee Members

J. M. Googe, R. W. Rochelle

Abstract

A flowmeter was designed and constructed to measure the average fluid flow over a ten-minute interval. The instrument used a bubbler system and differential pressure sensors to measure the density-compensated level in a sealed vessel. A microcomputer was used to record a fluid-level histogram and to calculate the slope of the histogram through a linear least-squares regression. The average flow is proportional to the slope of the level histogram. The instrument met or exceeded all requirements.

Files over 3MB may be slow to open. For best results, right-click and select "save as..."

Share