Abstract

The purpose of this investigation was to determine the potential use of a tungsten catalytic dissociator on an ammonia fueled internal combustion engine. The experimental data were to provide information on the effects of pre-dissociation (dissociating before entering the engine) on exhaust emissions. The data were also used to obtain a complete characteristic investigation of the electrically heated dissociator system. The final area of study was determining an economical method of operating the dissociators on a 1300 c.c. NSU test engine. This investigation took on the form of an energy utilization study.

The characteristic study of the tungsten catalytic dissociator system was performed for specially constructed dissociators supplied by the GTE-Sylvania Company. Two dissociator arrangements were investigated: a single dissociator, and two dissociators in parallel flow. The dissociators were operated to power levels of 2,000 watts, yielding ammonia flow temperatures up to 1700°F. The ammonia flow rate was varied from 0.4 lb/hr to. 5.4 lb/hr. Dissociation levels up to 81% were accomplished.

Without dissociation, unburned ammonia was exhausted from the test engine at a 20,000 ppm level, whereas by dissociating a portion of the fiow, the ammonia emissions were reduced to a level of 5,000 ppm. This was still an excessive amount of ammonia to be emitted to the atmosphere. Nitric oxide levels were increased by dissociation in the fuel-rich operating range and reduced by dissociation in the fuel-lean range.

In the energy utilization study results, it was found that the dissociator power level could be reduced to less than one kilowatt for the majority of data analyzed. Power level reduction by utilizing available power sources varied from 18% to 76%.

Design modifications were suggested which would give more catalytic surface area and longer ammonia contact time with the catalytic element, allowing operation of the dissociators at the lower power levels.

Degree
Master of Science
Major
Mechanical Engineering
File(s)
Thumbnail Image
Name

Thesis74.V552.pdf

Size

2.63 MB

Format

Adobe PDF

Checksum (MD5)

eac9b508100848f8d6679107301d5785


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science