Clad thickness measurement using dual frequency eddy current

Date Issued
December 1974
Author(s)
Hill, Jackie T.
Advisor(s)
W. E. Deeds
Additional Advisor(s)
H. C. Schweinler
R. L Becker
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/64059
Abstract

The purpose of this investigation was to determine the measurement accuracy of a dual-frequency eddy-current instrument for measuring the clad thickness of a conductor upon another conductor. The eddy-current instrumentation and measuring probe used were computer designed to minimize effects due to lift off and electrical conductivity (or resistivity) variations, and maximize the sensitivity to clad-thickness variations. The purpose of using two frequencies was to measure both the conductivity and thickness of the clads and to use the conductivity measurements to correct the thickness measurements for errors due to conductivity variations.

The experimental data were obtained from clads of two different conductivities and of various thicknesses. The base material had a conductivity value different from either of the clads. The resistivity ratios between the two different clad materials and the base material were approximately 1/2 and 1/3. The effect due to variation of lift off was minimized with a compensating circuit.

Responses from the measurements were in terms of voltage phase shifts. These phase shifts were later applied to a set of linear equations which were solved simultaneously to give an expression representing thickness. The constants in this expression were then set in a computer module, which plugs into the eddy-current instrumentation. The computer module used the constants and the measured phases to calculate the thickness of the clads.

It was determined that the dual-frequency technique measured clad thicknesses with better than a 99% accuracy. This accuracy is indicative of the thickness range incorporated in the phase responses applied to the set of linear equations.

Degree
Master of Science
Major
Physics
File(s)
Thumbnail Image
Name

Thesis74.H546.pdf

Size

2.17 MB

Format

Adobe PDF

Checksum (MD5)

bd022db1a37fcdb9f76c1eaee9e1fcc1


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science