Measurements of the surface resistance of a lead plated, superconducting, helically load cavity
The surface resistance of superconducting lead was measured at the frequencies 136.7, 233.9, 315.5, 395.9, and 471.6 MHz over a temperature range of 4.2K to 1.5K and compared to the calculated predictions of the BCS theory of superconductivity. The surface resistance measurements were made at low field levels up to the onset of the multipactor phenomenon. The variation of the surface resistance with field level was measured at 1.5K and, at some frequencies, at 4.2K also.
The measurements were made by using an evacuated, lead plated, helically loaded, copper cavity as the frequency controlling element in an oscillating loop. The thickness of the lead plating was estimated to be about 9 um from an integration of the electroplating current, but about 13 um to 16 um from measurements of the room temperature surface resistance of the plated cavity.
Measurements of the dc magnetic field along the axis of a second lead plated, helically loaded cavity were also made at room temperature, liquid nitrogen temperature, and 4.2K to search for the existence of trapped magnetic flux which may be thermoelectrically generated when the cavity is being cooled below the critical temperature of lead. The magnetic field magnitude was found to increase from a few tenths of a milligauss when the cavity was at room temperature or liquid nitrogen temperature, to ten to twenty milligauss after the cavity was cooled to liquid helium temperature. Observations of transient magnetic fields associated with transient thermal phenomena are described.
At 4.2K, even before subtracting a spurious contribution to the measured surface resistance caused by current flow through indium gaskets, the measured values and the theoretical values calculated from the BCS theory agree to within a factor of 1.8 at 136.7 MHz. They agree even more closely at the higher frequencies, the factor being 1.2 at 471.6 MHz. At 1.5K, well within the residual resistance region, the measured and theoretical values for surface resistance disagree by a factor as high as 120 at 136.7 MHz, down to a factor of 58 at 471.6 MHz. The measured residual resistance was found to increase as the 1.23 power of the frequency over the range of frequencies investigated. At 136.7 MHz and a cavity stored energy of 1 x 10-6 joule, which corresponds to a maximum surface magnetic field of about 2.0 gauss, a residual resistance of 4.6 x 10 -9 ohms was observed. This surface resistance corresponds to a cavity Q of 1.77 × 109.
Possible sources of residual resistance are briefly discussed and compared to measured results. A more detailed comparison is made with results predicted by a theory of Passow concerning a surface resistance component arising from phonon generation.
The magnitude and frequency dependence of the measured residual resistance are not exactly consistent with simple explanations. However, the magnitude is in good agreement with a simple model based on a trapped magnetic field of 12 milligauss, a value of trapped field consistent with measurements on a similar, but not identical, cavity. The magnitude of the observed residual resistance is also consistent with theoretical results from the phonon generation model of Passow.
The residual resistance showed no change with time over short time intervals as well as after a seven month time interval. Over this period of time the cavity temperature was maintained at liquid nitrogen temperatorr region.
The measured data are consistent with: the BCS theory in the weak coupling limit, a residual resistance independent of temperature, and an electron mean free path between about 580 A° and 5800 A°.