Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. Saturated pool and flow boiling studies with freon-113 and water at atmospheric pressure
Details

Saturated pool and flow boiling studies with freon-113 and water at atmospheric pressure

Date Issued
March 1974
Author(s)
Chapman, R. H. (Robert Hamilton)
Advisor(s)
H. W. Hofman
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/63948
Abstract

Research was undertaken to obtain an internally consistent data set from which convective flow boiling could be separated into its constituent pool boiling and forced-convection components and which could be used to test the adequacy of two commonly used correlations for predicting boiling heat transfer. Pool and flow boiling under saturation conditions at atmospheric pressure were studied using Freon-ll3 and demineralized water as test fluids. The same copper test surfaces, prepared by lapping with a 40o-grit compound, were used for all the tests. . Horizontal and vertical orientations were studied in the pool boiling facility; whereas the flow test facility was operated in the upflow mode. For the flow boiling tests, the mass flux was varied from 106,000 to 1,325,000 lb/hr·ft2 with Freon and from 106,000 to 852,000 lb/hr·ft2 with water. Convective boiling with Freon under annular flow conditions was investigated for a thermodynamic quality range of 2 to 8%, corresponding to a range of 4.1 to O.94 for the Martinelli parameter. Most of the data were characterized as nucleate boiling; relatively few data were obtained under suppressed nucleation conditions.

All the Freon flow boiling data were well correlated by the Rohsenow additive method. The annular flow data were not predicted by the relation proposed by Chen. This was attributed to failure of the Zuber expression, on which Chen's relation is based, to describe the pool boiling results adequately.

Aging effects of the copper boiling surface in the flow boiling tests with water (and to some extent in the horizontal pool boiling tests) caused excessive scatter and poor reproducibility in the data, negating correlation of the results with the Rohsenow additive technique. The data exhibited, however, the same general trends as observed with Freon.

Measured boiling coefficients and photography provided some evidence that steam bubbles in the water stream flowing past the test surface interfere slightly with the boiling performance; this effect was not observed in the Freon tests. Degradation in performance appeared related to bubble size; the steam bubbles were observed qualitatively to be two to three factors greater in diameter than the Freon bubbles.

No detectable surface orientation effect was found in the pool boiling studies with Freon. The results were well correlated by the Rohsenow pool boiling relation; the expression proposed by Zuber was inadequate. Measured coefficients for water boiling on vertical surfaces were found to be about l0% greater than those determined for horizontal surfaces. The results for pool boiling of water were reasonably well correlated with the Rohsenow expression but again the Zuber relation was deficient.

Based on the results of this study, the Rohsenow additive method is recommended for use with Freon-ll3 over the investigated range of mass flux and thermodynamic quality. Its use for higher mass fluxes and qualities is probably justified. Although the formulation of Chen's correlation facilitates its use, it is not recommended for application with Freon-ll3 in the mass flux and quality range studied. The results of this study suggest that modification to improve the nucleate boiling formulation are needed.

Metallographic examination of specimens prepared identically to the boiling test surfaces revealed a highly irregular surface (on a microscopic scale). High magnification micrographs obtained by ordinary optical techniques and by use of an electron scanning microscope are included.

Recommendations for further investigations are given.

Degree
Doctor of Philosophy
Major
Engineering
File(s)
Thumbnail Image
Name

Thesis74b.C380.pdf

Size

20.83 MB

Format

Adobe PDF

Checksum (MD5)

790cb84330ec4c9e28f4b363015279dc


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science