Planning, performing, and interpreting dynamic measurements in pressurized water reactors
Dynamic tests were performed on the Oconee I nuclear power system at 40, 75, and 95 percent of full power. The tests used pseudorandom binary and multifrequency binary perturbation of reactivity. Recordings were made of the resulting output of plant parameters including neutron power, steam pressure, pressurizer pressure, and reactor coolant outlet temperature. The results are presented in the form of frequency responses which are compared to the frequency responses predicted by a theoretical model of the system. The model parameters were adjusted for improved agreement between theory and experiment. From the parameter adjustment, the Doppler coefficient and effective coefficient of heat transfer from fuel to coolant were identified.
Detailed procedures are presented for performing dynamic tests in an operating plant environment with inherent system equipment and with minimal interference to power generation.