Liquid-film mass transfer coefficients were measured for carbon dioxide absorption into carbonate-bicarbonate solution from an air CO2 mixture in a packed column operated in concurrent flow. The packed section of the column was constructed from 10.2 cm I.D. pyrex glass pipe with two different packed lengths of 25.4 cm and 91.44 cm. A majority of the data were taken by using the shorter column to minimize wall flow. The packing for all experiments was one-half inch Raschig rings. Liquid superficial velocities were varied from 0.655 cm/sec to 2.65 cm/sec and the gas velocities were varied from 13.1 cm/sec to 56.5 cm/sec. These combinations of velocities go far beyond those possible in countercurrent operation.
Both the liquid film mass transfer coefficient, kL, and the effective interfacial area, a, were affected significantly by the liquid and gas velocities, and were somewhat higher than for countercurrent operation. Values of kL a were higher for concurrent flow by factors of two to three.
Values of kL a in the presence of a chemical reaction were higher than for physical operation. This is thought to be caused by the continued effectiveness of slow moving regions of the packed bed due to the reaction. With the taller column, values of effective interfacial area per unit volume of packing and kL were less than for the short column, which shows that the wall effect diminishes both quantities.