Urban runoff effects on water quality management
The purpose of this investigation was to use continuous water quality monitoring to provide information relating to the effects of urban stormwater from the Knoxville area during June 1975. In conjunction with this, similar data from the Cincinnati area were researched for May, 1975.
The experimental data for this investigation were obtained through the use of two Schneider Continuous Water Quality Monitors located downstream from Knoxville. Specific parameters monitored during this study include temperature, conductivity, pH, and dissolved oxygen. Readings at both sites were recorded once an hour by use of commercial telegraph lines connected to a central receiving station at the Water Resources Research Center, UT--Knoxville. Data for the Cincinnati area were obtained through the Ohio River Valley Water Sanitation Commission (ORSANCO) monitoring system.
Hourly rainfall data were obtained through the Tennessee Valley Authority (TVA) for the Knoxville urban area in order to establish runoff events. These data were plotted with water quality data to establish a relation between the two. Rainfall data on a daily basis for the Cincinnati area was obtained from the National Weather Service.
The results from Knoxville indicated a definite decrease in dissolved oxygen (D.O.) as a result of runoff events, this decrease sometimes violated stream standards. Temperature, conductivity, and pH were found to vary during runoff events. Cincinnati water quality data did not fluctuate as radically as the Knoxville data but similarities did appear with slightly lowered D.O. readings.
Thesis75.B698.pdf
2.6 MB
Adobe PDF
46330ac93a10458985798d9a6fbd06f5