Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Masters Theses
  5. A mathematical model for an integral economizer steam generator /c Don C. Arwood
Details

A mathematical model for an integral economizer steam generator /c Don C. Arwood

Date Issued
March 1975
Author(s)
Arwood, Don C.
Advisor(s)
T. W. Kerlin
Additional Advisor(s)
Julian E. Mott
P. F. Pasqua
J. C. Robinson
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/61490
Abstract

The purpose of this work was to formulate a linearized mathematical model for an integral economizer U-tube steam generator to predict its dynamic response during normal operational transients.

The model is a linear, lumped parameter type with a nodal structure suitable for matrix solution. The standard assumptions involving a nodal approach for dynamic analysis are made with the exception of the channel flow which is determined from the steady state momentum equation using the static head and frictional pressure drops.

The response of the model to four perturbations is presented and discussed along with some sensitivity analysis.

Degree
Master of Science
Major
Nuclear Engineering
File(s)
Thumbnail Image
Name

Thesis75.A796.pdf

Size

4.13 MB

Format

Adobe PDF

Checksum (MD5)

b13220313eaf799e1d6e2fe1d0673489


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science