The specific heat of tin from 300 to 1000K
The specific heat of solid and liquid tin has been measured in a dynamic adiabatic calorimeter from 300 to 1000 K. These values have then been used as a basis for estimating the contribution of anharmonic lattice vibrations to the specific heat in the solid state.
The specific heat of tin was measured using two types of samples. One was a high purity single crystal tin sample for which measurements were restricted to the solid state. The values were fitted to the polynomial
CP = 0.2352 x 102 + 0.1904 x 10-2 T – 0.2034 x 106/T2.
In the temperature range from 298 to 468 K, the standard error of estimate is 0.36 percent of the polynomial.
The majority of measurements were made on a sample prepared by melting high purity tin shot in a quartz container to permit measurements in the liquid state. The values, in the solid state, were fit by the polynomial
CP = 0.1808 x 102 + 0.2221 x 10-1 T – 0.1453 x 106/T2.
The standard error of estimate is 1.43 percent of the polynomial value. In the liquid state, the values were fitted by the polynomial
CP = 0.1917 x 102 + 0.6144 x 10-2 T – 0.1812 x 107/T2.
In this range, the standard error of estimate is 0.3 percent.
The specific heat at constant pressure, CP , was converted to values at constant volume by applying the dilation correction. A simple Debye Model, combined with electronic and vacancy contributions, was used to approximate a theoretical constant volume specific heat. Finally, the anharmonic specific heat of tin was determined by comparing the constant volume specific heat derived from experiments and the theoretical constant volume specific heat.
Thesis76.P353.pdf
3.59 MB
Adobe PDF
eeeb29734d5ca11cfb72a720f5db8209