A study of equipment calibration for an experimental automobile inspection project
Equipment employed in Project Auto/SEE, an experimental automobile inspection project, included a Bear platform brake tester, Hofmann and Sun roller brake testers, Marquette, Hamilton Standard and Sun engine analyzers, Beckman, Marquette, Sun and Horiba emissions analyzers, Weaver and Hunter wheel alignment testers and a Hunter headlight tester. Factory specified and/or specially designed methods and procedures were used for calibration of each test instrument. This study investigated the resulting calibration data to determine if the methods and procedures followed were sufficient or if additional methods should be used and what calibration schedule would be best suited for each piece of test equipment.
Results indicated a weekly calibration schedule for the Marquette engine analyzer voltmeter and spark advance scales and a twice-weekly schedule for all other scales. It was determined that a bi-weekly schedule would suffice for the Sun and Hamilton Standard engine analyzers. Twice-daily gas calibration of the Beckman, Marquette, and Sun emission analyzers and daily calibration of the Horiba analyzer was suggested. Weekly calibration was outlined for the Sun and Hofmann roller brake testers, while calibration data indicated that a bi-weekly calibration of alignment testers and weekly calibration of headlight testers should be performed. It was concluded that additional data for the construction of a control chart would be required to determine an acceptable calibration schedule for the Bear platform brake tester.
Thesis76.L683.pdf