An investigation of the accuracy of self-determined pulse rate in exercise

Date Issued
December 1976
Author(s)
Blazek, Mary Anne
Advisor(s)
Henry J. Montoye
Additional Advisor(s)
H. Alan Lasater
Edward T. Howley
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/60412
Abstract

Thirty young and middle-aged adults, previously instructed in measuring heart rates by palpation, were tested during two exercise sessions to determine the accuracy of their pulse counts. Subject-reported counts, taken for 10 seconds immediately after stopping exercise, were compared to a radioelectrocardiographic record obtained at the same time. A total of 12 post-exercise and 2 pre-exercise counts were recorded for each subject. All pre-exercise counts were taken at the carotid artery. Six of the post-exercise measurements were made at this same site, with the other six being taken at the radial artery, in random order.

Raw errors were calculated as the difference between heart rates measured by electrocardiograph (EKG) and by manual determination (i.e., EKG-subject count). Preliminary plots of error by exercise heart rate for all subjects indicated that the variation in radial pulse errors increased with heart rate, as did the magnitude of these errors. Carotid errors were largely unaffected by heart rate, maintaining a fairly constant variation over all ranges represented. The Friedman two-way analysis of variance yielded a significant Xr2 value (6.65; df=2; α=.05) for radial counts, but not for carotid, confirming the observed relationship.

Control charts, plotting mean error and range of error by subject, were used to identify individuals who made unusually large and/or variable counting errors. Average error (x), standard deviation (s), and standard error of the mean (sx), both between and within subjects, were then calculated for the sample, excluding atypical cases. With such cases removed, radial errors still tended to be larger and more inconsistent than carotid errors. When the Friedman two-way analysis of variance was performed again, the relationship of heart rate and error at the radial site was no longer significant.

Results of this study suggest that palpation, particularly at the radial site, is not an appropriate method of determining heart rate for certain individuals during activity. The carotid artery is to be preferred over the radial for greatest accuracy and repeatability, by those who have demonstrated the ability to utilize the technique. Limitations to current practice and recommendations for improvement are discussed.

 
Degree
Master of Science
Major
Physical Education
File(s)
Thumbnail Image
Name

Thesis76.B588.pdf

Size

3.73 MB

Format

Adobe PDF

Checksum (MD5)

7c70e800a5cad6dcbf203d8e3f9edcc6


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science