Abstract
Electrical earth resistivity was used in an attempt to monitor the expected contamination of groundwater by the Knoxville City Landfill. Over a period of ten months eight resistivity stations were occupied on a regular basis. Values of apparent resistivity were correlated, by simple graphical means and by multiple regression analysis, to water quality data obtained from observation wells. The results were generally inconclusive but a slight downward trend in resistivity evidently associated with an increase in contamination, is evident at two stations.