On pressure and heat flux distribution along magnetohydrodynamic generator channel-diffuser systems
The work reported here contains two parts. One part investigates the pressure distribution along supersonic magnetohydrodynamic (MHD) generators resulting from the interactions of Lorentz force and Joule heating with the flow. The other part studies the pressure recovery of diffusers under conditions pertinent to MHD generators.
Static pressure and voltage measurements were made in three diagonal conducting wall (DCW) generators with side wall angles of 45, 60, and 90 degrees (Hall). Measurements indicate the presence of shock waves in loaded generator channels at high interaction parameters (0.36). The pressure rise (relative to the non-MHD case) increases with increasing load, and the shock waves move upstream. A quasi one-dimensional analysis with friction, heat transfer, chemical reaction, and normal shock wave is made. The voltage distribution is predicted accurately by the analysis and so is the pressure where the flow is shock-free. The pressure prediction is less favorable when shock system exists, as there is a gradual pressure rise indicating the presence of an oblique shock wave system rather than one single normal shock as used in the computation. Due to the weak shock systems present, the power generation is not adversely affected. However, stronger shocks are detrimental to the generator performance.
Experimental investigations were made of both supersonic and subsonic diffusers with coal combustion gas with high entrance boundary layer blockage factors in the subsonic diffuser. It was found that a constant area supersonic diffuser performed adequately. The pressure recovery is approximately 0.6 of the normal shock recovery with a diffuser length of approximately 70 percent of generator channel length. The subsonic diffusers have a maximum pressure recovery coefficient (CP) of 0.76 with an inlet blockage factor (B) of 0.16 and decreases to 0.6 at a higher blockage factor of 0.20, with 6 degree half angle.
Due to the thick boundary layers existing in the subsonic diffusers, the quasi one-dimensional calculations are less satisfactory. An experimentally determined correction factor can be applied to account for the inlet boundary layer. They are presented in graphical form. Heat transfer rates for the channel diffuser system are also presented. Good agreement was obtained between the calculations and measurements.
Thesis77b.R68.pdf
10.39 MB
Adobe PDF
eb4727d1eaf2e7318bd751f6e6bca99f