Design theory for venturi scrubber performance
The parameters affecting venturi scrubber performance have been rationally examined and a new modeling theory developed that is consistent with most experimental observations. The performance model has been validated with available experimental data for a range of throat gas velocities, liquid-to-gas ratios and particle diameters and is used to study the heretofore undocumented effect on collection efficiency of several design parameters. Most striking among the discoveries is the prediction of little effect on collection efficiency with increasing values of liquid-to-gas ratio above about 15 gallons per thousand cubic feet. Indeed, for some cases a decrease in collection efficiency is predicted for liquid rates above this value. A graphical procedure for determining the value of design parameters, including a newly defined minimum contactor length, necessary for the collection of log-normally distributed particles at a desired efficiency is presented. Finally, a simplified form of the theoretical model is developed that includes the new design parameter of minimum contactor length, but does not require numerical equipment to evaluate.
Thesis77b.C772.pdf
4.77 MB
Adobe PDF
66e5ccfbf63174ce560771a633111692