  5. Part I: Application of pulse polarography and pulse anodic stripping to the determination of selected heavy metals in natural waters : part II: Application of controlled potential coulometric techniques to the determination of uranium
Details

Part I: Application of pulse polarography and pulse anodic stripping to the determination of selected heavy metals in natural waters : part II: Application of controlled potential coulometric techniques to the determination of uranium

Date Issued
June 1977
Author(s)
Crosmun, Sandra
Advisor(s)
John A. Dean
Additional Advisor(s)
James Q. Chamber
Robert A. McLean
T. R. Mueller
Donald C. Kleinfelter
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/60171
Abstract

The use of a thin mercury film wax-impregnated graphite electrode for the simultaneous determination of cadmium, lead and zinc in an acetate buffer by differential pulse anodic stripping voltammetry is described. Optimal instrumental parameters for maximum resolution and sensitivity for simultaneous analysis of these three elements in natural waters are discussed. The interference of copper with the determination of zinc is investigated in detail. An optimal mercury film thickness for this electrode is suggested.

 A method utilizing differential pulse polarography for the determination of chromium (VI) in natural water is described. Additions of 0.62 µg Cu(II) ml-1 and 0.55 µg Fe(III) ml-1 did not interfere with the determination of 0.050 µg Cr(VI) ml-1. The natural water samples containing Cr(VI) were buffered to approximately pH 7 with 0.1 M ammonium acetate and 0.005 M ethylenediamine and analyzed. Natural water samples of chromium from 0.035 µg to 2.0 µg•ml01 may be analyzed directly without further preparation. The detection limit is 0.010 µg•ml-1

. A novel, highly efficient cell with integral stirrer for controlled potential coulometry is described. This cell was used to demonstrate the feasibility of determining uranium (VI) by predictive coulometry. A PDP 8/I minicomputer was used to predict the coulometric endpoint with high accuracy within 2.5 minutes in a titration which normally takes about 10 minutes. This technique was shown to yield acceptable results even in the presence of an interfering phosphate matrix.

 
Degree
Doctor of Philosophy
Major
Analytical Chemistry
File(s)
Thumbnail Image
Name

Thesis77b.C768.pdf

Size

4.61 MB

Format

Adobe PDF

Checksum (MD5)

fd9de920aa5dbea64d55d6df059f9ab8


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science