Surfactant mediated development of High resoulution open capillary liquid chromatography
In terms of selectivity, High Performance Liquid Chromatography (HPLC) is one of the most attractive methods for chemical analysis. In its present "state of the art" form, however, it lacks the separation power necessary for complex sample analysis. Separation power is attained through the achievement of high chromatographic efficiency. This dissertation discusses some of the approaches that have been taken to increase column efficiency in HPLC by improving packed columns, but illustrates that the most promising way to ultimately achieve this goal is by developing methods in open capillary liquid chromatography (OCLC).
One of the major impediments to development of OCLC has been column occlusion. This problem has occurred most frequently during column fabrication due to precipitation of organosilanating reagents within the narrow flow channels associated with open capillary columns (<20 µm). In this dissertation, a technique referred to as Dynamically Modified OCLC is described and compared to OCLC with covalently bonded stationary phases in terms of both capacity and efficiency. In Dynamically Modified OCLC, surfactants are used to create stationary phases which facilitate separations. Surfactants that are employed are totally soluble in the reversed-phase solvents used, so no precipitation occurs within the column. The use of surfactants in this case successfully addresses the problem of column occlusion and brings the development of OCLC closer to being realized. Two problems that were not addressed, however, were the small capacity factors exhibited by these columns, as well as the stringent detector requirements imposed by the necessity to use extremely small diameter columns (<10 µm). The latter problem was a result of using hydrostatic pumping to drive the separation.
Micellar Electrokinetic Capillary Chromatography (MECC) is a new method in OCLC that removes the aforementioned limitations. In MECC, surfactants are used above the critical micelle concentration (CMC) in largely aqueous mobile phases. Columns are pumped electrokinetically, and for reasons described in this dissertation larger diameter columns can be used, thereby allowing more flexibility with respect to detection. In order to develop MECC for complex sample analysis, it was first necessary to address its inherent problems. Specifically, the major limitation of MECC was its limited peak capacity. Since separations are based on partitioning of solutes between two distinct phases (aqueous and micellar) which are both moving through the column in the same direction, but at different velocities, it is necessary to successfully resolve all solute bands between these two respective elution times.
The latter part of this dissertation describes methods that have been developed to control the flow velocities of these phases thereby allowing adjustment of the elution range in MECC. In addition, methods are described for carrying out gradient elution in MECC, and they are characterized in terms of classical chromatographic parameters.
Thesis87b.B257.pdf
4.45 MB
Adobe PDF
93b77e748037a0a4cd68bb0030adfe6f