Assessment of the containment response of an advanced PWR to selected severe accident sequences
A limited severe accident assessment of a postulated advanced pressurized water reactor (APWR) design is performed and is based, in part, on requirements provided by the Electric Power Research Institute Advanced Light Water Reactor Utility Requirements Document. The work includes the installation of the Modular Accident Analysis Program (MAAP) on a personal computer, development of a summary screen, benchmarking the MAAP code to baseline assessments, the development of a pseudo-APWR model, and an assessment of the containment response of the APWR to selected severe accident sequences. The results of this assessment are then compared to those provided for similar current generation plants.
The benchmark exercise was performed successfully and no significant variance in the major parameters was identified. Based on the severe accident assessment, the overall conclusion drawn from the assessment is that the APWR design offers additional safety margin for mitigating severe accidents. The main improvement is the plant response to high pressure melt ejection (HPME). Improvements are also noted in precluding basemat failure and late containment overpressurization.