Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Masters Theses
  5. Application of high performance liquid chromatography to the study of dissolved organic phosphorus compounds released by algae
Details

Application of high performance liquid chromatography to the study of dissolved organic phosphorus compounds released by algae

Date Issued
March 1977
Author(s)
Hixson, Samuel Winton
Advisor(s)
Roger A. Minear
Additional Advisor(s)
Dennis W. Weeter
Robert L. Jolley
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/59138
Abstract

The development of an analytical technique utilizing high performance liquid chromatography (HPLC) for separating the inositol phosphates was studied. Commercial inositol hexaphosphate (IHP) and inositol monophosphate (IMP) were adequately separated from each other on Aminex A-27 resin with ammonium bicarbonate as the eluent. A breakdown of the organic bound phosphorus to orthophosphate occurred while on the HPLC column. This breakdown procedure could be speculated to be due to an alkaline hydrolysis process. Chromatograms of solutions initially containing only IHP yielded four peaks which appear to be best ascribed to residual IHP and the intermediate inositol phosphates containing 5, 4, and 2 phosphate groups per molecule. IMP clearly was not an intermediate of IHP hydrolysis on the LC column.

Dissolved organic phosphorus compounds released by the culture Chlamydomonas reinhardtii were subjected to preliminary separation on Sephadex G-25. Sephadex G-25 fraction, which was equal to the inositol phosphate elution position, was chromatographed on the HPLC and resulted in only the orthophosphate peak being identified. This HPLC chromatogram showed that a preliminary clean-up procedure was needed prior to HPLC separation. Alkaline bromination was chosen as the clean-up procedure since all the non-inositol phosphates would be oxidized. Samples from the culture study were subjected to alkaline bromination and then chromatographed on Sephadex G-25 before being placed on the HPLC. The results of the HPLC showed three major peaks which did not match any of the inositol phosphate standards. Alkaline bromination followed by re-chromatographing the Sephadex fractions resulted in one peak at the elution position of IMP, thus providing marginal evidence for the presence of this compound in the culture solution.

 
Degree
Master of Science
Major
Environmental Engineering
File(s)
Thumbnail Image
Name

Thesis77.H598.pdf

Size

2.51 MB

Format

Adobe PDF

Checksum (MD5)

367e0c437590b2e112a863e502dde0f9


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science