Determination of the rheological properties of non-Newtonian fluids with a Hoeppler Rheo-Viscometer
Date Issued
August 1977
Author(s)
Hereford, Robert Butler
Advisor(s)
J. Eric Schonblom|
Additional Advisor(s)
John Jayne
William T. Snyder
Abstract
A method is presented in which the relationship between the average wall shear stress and the apparent wall shear rate can be determined for non-Newtonian fluids by performing experiments with a Hoeppler Rheo-Viscometer. The equations are obtained by applying a technique previously used to predict non-Newtonian flow behavior in ducts. The technique is expanded to include the varying cross-section of the slit between the ball and tube.