Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Masters Theses
  5. Preliminary investigation of reaction time of color deficient observers to the 3M Dual Indication Signal
Details

Preliminary investigation of reaction time of color deficient observers to the 3M Dual Indication Signal

Date Issued
June 1977
Author(s)
Heid, John W.
Advisor(s)
Jack B. Humphreys
Additional Advisor(s)
William L. Grecco
John N. L.
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/59128
Abstract

The Dual Indication Signal was developed and is manufactured by the 3M Company. The purpose for which it was originally designed was to allow the green and yellow arrow indications in traffic signals to be displayed from one section. Preliminary investigation and actual intersection tests did not produce any problems for this use of the dual indication signal. The results were presented to the U. S. Department of Transportation and accepted. The Manual on Uniform Traffic Control Devices was amended to permit the yellow and green arrows to be displayed in one section.

This research investigated another use for the dual indication signal in conjunction with the above permissible use. The dual indication signal displayed the green and yellow circular indications as well as the green and yellow arrows.

The investigation compared the dual indication signal having five indications in three sections with a five section signal that is commonly used for left turn control at intersections. This was accomplished by recording the reaction times of subjects to each signal to obtain an average reaction time for each indication. The actual testing was conducted outside with the subjects approximately 150 feet from the signals. This procedure was used to approximate actual driving conditions. Color deficient subjects were used in the testing as well as noncolor deficient subjects.

The average reaction times for each indication were statistically analyzed providing 98% confidence intervals for the means of reaction times to each indication. This was calculated for each group of subjects.

The investigation produced some very interesting results. First, there does not appear to be a difference between the reaction times of color deficient and noncolor deficient observers. Second, there does appear to be a difference between the two signals for the total population. Both the color deficient and noncolor deficient subjects had longer average reaction times to the dual indication signal displays than to the five section signal displays for three of the four cases studied. The yellow circular indications' response time had the greatest difference with a range between 0.2 and 0.6 seconds. The response time for the green circular and yellow arrow indications had differences that range between 0.0 and 0.2 seconds and 0.0 and 0.3 seconds respectively. The observers of the green arrow indications could have reaction times that are the same.

Recommendations include additional study to isolate the causes for the differences in reaction times and additional time being mandatory if the use of the dual indication signal is allowed for the yellow circular indication. The additional time for the yellow circular indication should be at least 0.5 seconds. The dual indication signal section should also be restricted to intersections with high visibility.

 
Degree
Master of Engineering
Major
Civil Engineering
File(s)
Thumbnail Image
Name

Thesis77.H353.pdf

Size

2.47 MB

Format

Adobe PDF

Checksum (MD5)

6b5016b43ad997f6aabd0cec6390f6e8


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science