The shunt impedance measurements of the spirally loaded cavities
Based upon the recent interest in spirally loaded resonant cavity (SLC) to be employed as an accelerative structure in room temperature linear accelerators, a series of measurements was initiated on three models of spirally loaded copper cavities with spirals having circular cross sections developed at the Oak Ridge National Laboratory.* The purpose of the measurements was to study shunt impedance. The mathematical models used were based upon the treatment of the SLC as a shorted quarter wave transmission line configured as a loosely wound spiral enclosed in a large container.
The main objective of this thesis is to investigate the bare shunt impedance of the SLC as a function of the structure length in an attempt to find the optimum structure length parameter. The experimental data for investigation were obtained from three sets of measurements which in turn were obtained by progressively cutting down the structure lengths of three initial cavities.
The experimental results were also compared against theoretical shunt impedance curves for spirals having circular cross section. The theoretical curves aid in
*Work reported was sponsored by the U. S. Atomic Energy Commission under contract with Union Carbide Corporation determining the quality of the constructed cavity, and in inferring the optimum structure length.
Thesis77.P378.pdf
2.3 MB
Adobe PDF
bfe6233cb79dac98404e722d14165a58