Energy consumption of pressure saucepans at 5-, 10- and 15-pounds pressure in relation to source of heat when held for 5, 15 and 25 minutes
This experiment was designed to evaluate the preheat time and watt-hour consumption of electric and nonelectric pressure saucepans heated on smooth-top and tubular encased surface units. Data was collected in three replications.
The experiment was completed in an environmentally controlled laboratory. The controlled factors were quantity and hardness of water, voltage of circuit, size and position of the surface unit on the range, placement of the pressure saucepans on the surface units and holding time.
Significant differences at 5-, 10- and 15-pounds pressure in preheating time between electric and nonelectric pressure saucepans heated on smooth-top and tubular encased surface units were hypothesized. Significant watt-hour consumptions while preheating and holding the pressures for 5, 15 and 25 minutes were also hypothesized.
The nonelectric Mirro-Matic heated on the tubular unit was the quickest to preheat and the slowest on the smooth-top surface unit. The electric Presto required the least watt-hours at 5- and 10-pounds pressure. The electric Presto and nonelectric Mirro-Matic on the smooth-top surface unit consumed less energy and were significant from the nonelectric Mirro-Matic or nonelectric Presto on the tubular encased surface unit and the nonelectric Presto on the smooth-top surface unit.
Thesis77.L335.pdf
1.69 MB
Adobe PDF
150b63bf084b6079b3c320caca6804ec