Gamma heating measurements in LMFBR shields with thermoluminescent dosimeters
An important and relatively new application for the thermolumine-scent dosimeter (TLD) is the direct and simultaneous measurement of gamma-ray energy deposition distributions in heavy metal shields typical to fast breeder reactors. This dissertation describes the development of a TLD dosimetry system capable of measuring gamma-ray energy deposition in a mixed (neutron and gamma-ray) radiation field to within ±3% on an absolute basis. This work includes a detailed evaluation of the experimental techniques normally employed in TLD dosimetry, the verification of the gamma-ray spectral correction factor used to relate the energy deposition in the TLD to that occurring in the sleeve material, and the development of new neutron dose correction factors for both CaF2:Mn and 7LiF thermoluminescent materials.
An important phase of this work was the verification that the cavity ionization theory is a suitable basis for the gamma-ray spectral correction factor. A semiempirically derived general cavity ionization theory using two extreme cases for small and for large cavities was developed in this study. The measured responses of CaF2:Mn and 7LiF TLDs were compared with discrete ordinates calculations for the transmission of 51Cr, 137Cs, 60Co, and 24Na isotopic gamma rays through iron slabs. It was confirmed that TLD experimental techniques were capable of very accurate (±2%) energy deposition measurements in a pure gamma-ray field.
The second and very difficult phase of this work was the calculation of neutron response factors for CaF2:Mn and 7LiF TLDs. A calculational model was developed to determine neutron responses of the dosimeter materials using neutron interaction cross sections, charged particle efficiency versus stopping power, and nonescape probability of charged particles from the dosimeter.
The energy deposition distributions due to gamma rays within various reactor shielding configurations were measured with CaF2:Mn and 7LiF TLDs and with a high pressure iron-equivalent (argon-krypton) ionization chamber. Comparison of these results with discrete ordinates calculations provided a reasonable basis for the evaluation of existing and newly developed neutron response factors. The use of these neutron dose correction factors together with careful execution of measurement, readout, and spectral correction procedures yielded results accurate to within ±3% on an absolute basis in the gamma-ray heating measurements.
Thesis78b.Y665.pdf
9.29 MB
Adobe PDF
aec7cb74beb148d363d685b0a9c1dba0