Search for New Physics in the Decay H → ZΥ(nS) with the CMS Detector at the Large Hadron Collider
Date Issued
May 2026
Author(s)
Harris, Jesse
The University of Tennessee
Advisor(s)
Stefan Spanier
Additional Advisor(s)
Eric Lukosi
Robert Grzywacz
Lawrence Lee
Abstract
Rare decays of the Higgs boson provide sensitive probes of physics beyond the Standard Model, as potential modifications to Yukawa couplings or additional loop contributions can enhance branching fractions beyond Standard Model expectations. In particular, the decay
$\rm{H} \rightarrow \rm{Z} \Upsilon (nS)$, $n = 1,2,3$ offers a clean experimental signature through fully leptonic final states but requires excellent tracking resolution, vertex reconstruction, and lepton identification in a challenging, high-occupancy environment. Using 140~fb$^{-1}$
of proton-proton collision data at
$\sqrt{s} =13$~TeV collected by CMS, events with dilepton decays of both the
\rm{Z} boson and $\Upsilon(nS)$ meson were analyzed with machine learning techniques for background discrimination. No significant excess was observed, and an expected 95\% confidence level upper limit on the branching fraction of
$9\times 10^{-4}$
was obtained, approximately 31 times the Standard Model prediction.
Extending the sensitivity of such searches at the High-Luminosity LHC (HL-LHC), where proton-proton collisions will be delivered at luminosities an order of magnitude higher than previous runs, requires detectors capable of maintaining precise charged-particle reconstruction under substantially increased radiation levels and pileup. To meet these demands, the CMS pixel detector is being upgraded with high-granularity hybrid silicon sensors bump-bonded to a custom readout integrated circuit, CROC~v2, designed for fine segmentation, fast readout, and radiation tolerance.
This work contributes to the development and validation of the CMS HL-LHC pixel system through both hardware qualification and performance studies. Prototype and pre-production sensor-chip assemblies from multiple vendors were evaluated using a manual probe station and electronic charge-injection techniques to assess connectivity, functionality, and reliability prior to large-scale production. In addition, the production-version CROC~v2 was irradiated to 1.6~Grad using a
$^{60}$Co $\gamma$-ray source while operated near its nominal temperature of
-20$^{\circ}$C. Continuous monitoring of internal voltages, pixel response, and diagnostic structures demonstrated stable operation and performance consistent with design specifications at the target radiation dose. Together, these efforts help ensure that the upgraded pixel detector can sustain the demanding HL-LHC environment and enable increasingly sensitive searches for rare Higgs decays and other phenomena beyond the Standard Model.
Degree
Doctor of Philosophy
Major
Physics
File(s)![Thumbnail Image]()
Name
HARRIS-PRIMARY-2026.pdf
Size
12.32 MB
Format
Adobe PDF
Checksum (MD5)
3ddac49953eef0e8979917a92af2017e