PERFORMANCE AND SAFETY CONSIDERATIONS FOR THE IMPLEMENTATION OF A PWR-BASED INTEGRATED ENERGY SYSTEM
Date Issued
May 2026
Author(s)
Lindsay, Isabelle Ottillia
The University of Tennessee
Advisor(s)
Nicholas Brown
Jamie Coble
Additional Advisor(s)
G. Ivan Maldonado
Vivek Agarwal
Abstract
Nuclear energy is the United States’ largest source of ultra-low carbon energy and is integral to our pursuit of clean energy and combat against climate change. However, many currently operating nuclear power plants are at risk of early closure due to the economic challenges. To mitigate this issue and preserve this source of clean baseload energy, nuclear power can be used in an Integrated Energy System (IES) to produce a secondary product or support a secondary process, such as hydrogen production, desalination, and data center support. Additionally, flexible operation modes can also be introduced to follow electricity market demands and optimize profits.
This work presents two topics. First, what is the expected fuel performance for a high burnup PWR system used for flexible operation? What are the most influential flexible operation parameters? This question was answered using a fuel performance Sobol sensitivity analysis. The analysis found that plenum pressure and cladding hoop strain limits, though infrequently, were exceeded during normal operation with flexible parameters. This work concluded that the life-average linear heat rate and the power scaling factor were highly influential inputs, while the ramp rate and interval length didn’t notably impact predictions.
Secondly, what is the expected system response of a loss of heat sink transient in a typical PWR system used for flexible operation? This question was answered using a RELAP5-3D analysis of a loss of feedwater flow transient described in the Vogtle Electric Generating Plant Units 1 & 2 Final Safety Analysis Report scenario 15.2.7, “Loss of Normal Feed Water Flow.” The results demonstrate behavior similar to the behavior presented in the FSAR, though the analysis resulted in a faster progression of events and more extreme pressurizer responses. A reduction in flow through the core results in higher outlet temperatures and higher pressurizer pressures. There is not a notable change in transient behavior beyond minor differences in pressurizer behavior observed for up to a 50% flow reduction. As such, a greater than 50% mass flow rate reduction is required to substantially changing the expected behavior of the system during a loss of feed water flow transient.
Degree
Doctor of Philosophy
Major
Nuclear Engineering
Embargo Date
May 1, 2027