  5. A Transformer Flux Balancing Scheme Based on Magnetizing Current Harmonic for Medium Voltage Dual-Active-Bridge Converters
Details

A Transformer Flux Balancing Scheme Based on Magnetizing Current Harmonic for Medium Voltage Dual-Active-Bridge Converters

Date Issued
May 2022
Author(s)
Gao, Zihan  
University of Tennessee at Knoxville
Advisor(s)
Fei "Fred" Wang
Additional Advisor(s)
Hua "Kevin" Bai
Han "Helen" Cui
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/57520
Abstract
The transformer saturation in Dual-Active-Bridge (DAB) converters could be a critical issue. One of the reasons for the transformer saturation is the flux unbalance, including steady-state and transient unbalance. The steady-state flux unbalance is led by converter circuit parameters and modulation mismatch, while the transient unbalance is caused by the ill-managed switching timing during load or control transient. As higher rating wide-bandgap devices becoming available, the converters can be designed with higher power density and efficiency by pushing less margin on materials, which makes the flux balancing and avoiding saturation more important a problem. As medium voltage DC/DC converters have more demanding requirement on insulation, noise, or sensitivity, the implementation of conventional methods become challenging. This thesis mainly focuses on a transformer flux balancing scheme, including both flux unbalance detection and control, based on the second-order harmonic component in the transformer magnetizing current. First, the ferrite gaps are used in the transformer cores to create partial saturation and non-linearity magnetizing current. The non-linearity of current introduced by the magnetic gaps is then studied, in both time and frequency domains. The mathematical link can be found between the DC bias component of the transformer flux and second-order harmonic in the magnetizing current. Magnetic current sensors are also designed dedicated for both unity and fractional transformer winding ratios. With the proposed transformer non-linearity and designed sensor, the flux balancing control can be implemented with modulation adjustment. The non-linearity of ferrite gaps, transformer magnetic current sensors, and flux balancing scheme are all validated through test, on both 850/850 V and 850/6700 V DAB converters. Through the analyses and tests, the proposed scheme can effectively balance the transformer flux without requiring effort on explicit effort on calibrating sensors or control algorithm.
Subjects

Flux balancing

Dual-active-bridge co...

DC bias

magnetic saturation

Disciplines
Electrical and Electronics
Power and Energy
Degree
Master of Science
Major
Electrical Engineering
File(s)
Thumbnail Image
Name

GaoThesis_2022.pdf

Size

11.15 MB

Format

Adobe PDF

Checksum (MD5)

8aa83261881bd7921d99fb6f84fa8dfb


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science