Pressure drop effects of particle size distribution modification on the performance of fabric filtration due to cyclone precleaning of gas flows
The primary objective of this research was to examine the effects of particle size distribution modification, resulting from the cyclonic precleaning of dust-laden gas flow, on the pressure drop performance of fabric filtration media. Moreover, the relationship of overall cyclone collection efficiency on system pressure drop (summation of pressure losses across both fabric filter and precleaning cyclone) was studied.
This study, in part performed on laboratory scale equipment, revealed that there was a minimum system pressure drop value associated with cyclone and fabric media type and operating conditions which was obtained for a given inlet dust size distribution at a specific cyclone efficiency. At this optimum cyclone efficiency, the system pressure drop savings of a cyclone/fabric filter combination as compared to a fabric filter alone were generally found to be substantial. However, as cyclone efficiency exceeded its optimum value, system pressure drop rose rapidly and not only quickly negated any pressure drop savings achieved through the use of a precleaner, but increased operating pressure losses above those values at which a fabric filter would operate without a precleaner. For this reason the establishment of an optimum precleaner efficiency for a cyclone/fabric filter control device is deemed important.
A modeling technique was derived in this study to predict system pressure drop as a function of cyclone efficiency. Using laboratory generated data, graphical relationships were generated which through data interpolation provided inputs to the developed model. A unique relationship was found between the geometric mass mean diameter, dpg-out, of the particulate penetrating through the cyclone, and the operating pressure drop across the fabric filter dust cake as a function of dust loading. This empirical relationship was then used to predict fabric filter pressure loss as a function of cyclone efficiency.
An optimization capability was added to the derived cyclone/fabric filter model with the development of a theoretical subroutine to predict the previously found graphical model inputs (with the exception of the fabric pressure loss/dpg-out relationship which must be empirically found). With the incorporation into the expanded model of a pressure loss expression for a commercial series of cyclone sizes, the expanded model with optimization routine was used to predict the optimum cyclone inlet velocity for each cyclone size which resulted in the optimum cyclone efficiency and the minimum system pressure drop for a given inlet dust size distribution, cyclone and fabric media type, and operating conditions.
Results of the modeling analysis substantially delineated the effect that a cyclone precleaner has on cyclone/fabric filter system pressure drop. Effects of varying cyclone diameter, inlet particle size distribution, and cyclone inlet velocity were studied. This modeling technique should be useful as a tool to aid in the optimum design of cyclone/fabric filter collectors with a minimum annualized cost.