Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. Cyclic amp, microtubules and mammalian cell shape : a study with Chinese hamster ovary cells and their morphological variant
Details

Cyclic amp, microtubules and mammalian cell shape : a study with Chinese hamster ovary cells and their morphological variant

Date Issued
March 1978
Author(s)
Borman, Linda Suzan
Advisor(s)
Abraham W. Hsie
Additional Advisor(s)
Ray W. Tennant
Frank H. Gaertner
J.M. Holland
Donald Swartzendruber
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/56945
Abstract

Treatment of Chinese hamster ovary (CH0)-Kl cells with Bt2cAMP results in cell elongation and alterations in numerous other physiological properties of the cells. I have isolated a morphological variant of CH0-Kl cells, M-7, which does not elongate after treatment. Characterization of the variant with respect to cell morphology, agglutinability with plant lectins and saturation density of growth showed that the responses of these properties to Bt2cAMP treatment is similar to that observed in the parental cells, with the exception of cell morphology. In this regard, phase contrast microscopy showed that treatment of the variant changes its rounded cell shape into a more spread and epithelial-like shape whereas the parental cell changes from an epithelial-like-shape to a fibroblast-like morphology after treatment. The possible role of microtubules in CHO cell shape was examined by a TEM study of cells sectioned at three vertical levels of the cell-bottom, middle, and top with respect to the substratum surface. Data showed that the parental Kl cell increases its microtubule number and orientation at the middle and bottom levels of the cell after treatment. The treated variant, M-7, however, increases its microtubule number at all three levels of the cell but does not show an increase in microtubule orientation at any level. Measurement of the total quantity of assembled microtubules in Kl and M-7 cells (microtubule number/unit cytoplasm x microtubule length) at each level of section showed that on a whole cell basis, M-7 cells contain approximately half the quantity of microtubules found in Kl cells, with or without treatment. However, both and M-7 cells increase their microtubule amount by a similar increment after treatment. The failure of M-7 cells to orient microtubules after treatment is probably not due to a defect in the orientation process, per se, because I observed in the TEM study that Kl and M-7 cells, in cell contact with neighboring cells, orient their microtubules beneath the plasma membrane of the contact site to the same extent, as measured by microtubule length. Therefore, it may be that the low quantity of microtubules present in M-7 cells is insufficient for orientation and thereby prevents cell elongation. Because microtubules are polymers of the protein tubulin, I investigated the possibility that the tubulin molecules in M-7 cells are altered or are present in a low concentration in the cells, resulting in a poor capacity for polymerization. This was examined by the specific binding of colchicine to tubulin. The results showed that Kl and M-7 cells contain the same amount of colchicine-binding activity and that the binding properties of both cell types are similar. Therefore, I propose that M-7 cells have a defect in the polymerization process for cytoplasmic microtubules. This causes its low quantity of microtubules under control conditions and perhaps its round cell shape. After Bt2cAMP-induced increases in microtubule polymerization, the quantity of microtubules in M-7 cells remains too low for cell elongation to occur, a process which probably involves microtubule orientation.

Degree
Doctor of Philosophy
Major
Biomedical Science
File(s)
Thumbnail Image
Name

Thesis78b.B669.pdf

Size

7.79 MB

Format

Adobe PDF

Checksum (MD5)

bebe6ba8f0e49e35b2af5bce2813b9e6


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science