Mass transfer in two-phase cocurrent downflow
The purpose of this study was to examine the mass transfer behavior between a gas and a liquid during cocurrent downflow of the two-phase mixture in an open tube. Liquid-film mass transfer coefficients and interfacial areas were measured separately by the chemical absorption of carbon dioxide from an air-CO2 mixture into solutions of sodium hydroxide. The absorption column fabricated for this study was made of 1-inch I.D. pyrex glass pipe with a test section length of 8.13 feet. Experiments were conducted in the falling bubbly-film and froth flow regimes at liquid velocities ranging from O.30 to 1.50 ft/sec and gas velocities from 6 to 20 ft/sec.
Both the liquid-film mass transfer coefficient and the interfacial area were affected significantly by changes in the liquid and gas velocities. The interfacial area reached a maximum during the transition between flow regimes. These data lay well within the range of values of interfacial area reported in similar studies. Mass transfer coefficients increased with increasing liquid velocity, although the converse was true with increasing gas velocity. An explanation for this behavior at the present level of understanding of two-phase flow would be only speculative. Mass transfer coefficients measured in this study exceeded the values reported in similar two-phase flow studies by a factor of as much as 2.5. When compared with other absorption techniques, this factor approaches 6.
This work provides a basis for the further study of mass transfer characteristics in other flow regimes. Alternative analytical methods such as gas-phase chemical analysis to determine rates of absorption should be considered for applicability to a variety of flow regimes. Also, studies on the effect of system physical properties would provide a foundation for the development of mass transfer correlations in cocurrent gas-liquid downflow.
Thesis78.V387.pdf
2.57 MB
Adobe PDF
28864c90cc161a32a5939934da1018b3