A comparison of three different flammability testers using top and bottom weight cotton, polyester, and cotton/polyester blend fabrics

Date Issued
December 1978
Author(s)
Thompson, Beth Ann
Advisor(s)
Anna Jean Treece
Additional Advisor(s)
Charles Noel
Tyrone Vigo
John Philpot
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/56897
Abstract

The objectives of this research were to determine the effectiveness of the MAFT compared to the 45° angle tester and the vertical tester, as a test method for the flammability of general wearing apparel, and to determine the effect of fabric fiber content and fabric weight on the maximum heat transfer rate, time to reach maximum heat transfer rate, and total heat transfer as measured by the MAFT according to the draft proposed standard.

A total of eight fabrics was evaluated on each of the three instruments according to their respective specified procedures. One top weight and one bottom weight fabric with each of the following fiber contents--100% cotton, 50%/50% cotton/polyester, 65%/35% polyester cotton, and l00% polyester--were evaluated on the 45° angle tester, the vertical tester, and the MAFT.

A comparison of the three flammability testers and test methods was completed on a pass/fail basis in terms of end use as shirts/blouses or pants/slacks using Cochrans-q statistical procedure.

A 4 x 2 analysis of variance was used to evaluate the effects of the two independent variables (fabric fiber content and fabric weight) on three dependent variables (maximum heat transfer rate, time to reach maximum heat transfer rate, and total heat transfer).

Data revealed the vertical test method differed from the 45° angle test method and the draft proposed standard on a pass/fail basis in terms of fabric end use. The vertical test "failed" six of the eight test fabrics, while both the 45° angle test and MAFT test "passed" all eight test fabrics. The vertical test limited the fabrics more severely than the 45° angle test and the MAFT test. No change was observed between the 45° angle test and the MAFT test as defined in this study. However, it must be noted that even though all eight fabrics "passed" the MAFT test as defined in this study, the eight fabrics did not all fall into the same classes as outlined in the draft proposed standard; this would further limit the end use for some of the test fabrics, whereas the 45° angle test would not.

The effect of fabric fiber content on the maximum heat transfer rate, time to reach maximum heat transfer rate, and total heat transfer was consistent within each fabric weight category. The 50%/50% polyester/cotton and 65%/35% polyester/cotton top weight fabrics exhibited higher values for each of the dependent variables, with the 100% cotton ranking third and the 100% polyester ranking fourth. The bottom weight fabrics exhibited increasing values for the dependent variables with increasing amount of cotton content. A significant interaction between the independent variables, fabric fiber content and fabric weight, was observed for the 100% cotton.

The effect of fabric weight was observed as an increase in the values for the maximum heat transfer rate, time to reach maximum heat transfer rate, and total heat transfer between top and bottom weight for all fabrics, except the 100% polyester. The l00% polyester did not ignite.

Degree
Master of Science
Major
Textiles and Clothing
File(s)
Thumbnail Image
Name

Thesis78.T542.pdf

Size

1.41 MB

Format

Adobe PDF

Checksum (MD5)

b1293799221395d3785ade95757783ec


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science