Abstract

A conventional production model split-unit air-to-air heat pump was installed in an unconventional manner in a residence in Oak Ridge, Tennessee. This installation involved ducting installed on the west end of the house to connect either the attic space air or the crawl space air to the outdoor package of the split-unit heat pump. After passing over the outdoor heat exchanger, the air was then exhausted back to ambient. Either the solar-assisted installation (attic space air) or the single-pass geothermal installation (crawl space air) could be selected by use of a damper. A third installation was investigated analytically for a sealed crawl space where the "outdoor" package would be physically in the crawl space and would recirculate the crawl space air (recirculating geothermal installation).

Temperature data were collected for the solar-assisted and single-pass geothermal installations. The temperature data collected in the solar-assisted installation were used to determine the net effect the installation had on the consumer's heating bill. The temperature data collected in the single-pass geothermal installation were used to verify an analytical method of calculating the net benefit this installation would yield on a consumer's five-month heating bill for Oak Ridge, Tennessee.

The findings of this preliminary investigation show that the solar-assisted installation as tested gave a net loss of about O.2% over the five-month period. The analytical projection, checked where possible with experimental data, showed that the single-pass geothermal installation would give a net saving of 22.5% on a five-month heating bill. The analytical projection for the recirculating geothermal installation predicts a 3l.5% net saving for a five-month heating bill in Oak Ridge, Tennessee.

Degree
Master of Science
Major
Mechanical Engineering
File(s)
Thumbnail Image
Name

Thesis78.S3541.pdf

Size

2.4 MB

Format

Adobe PDF

Checksum (MD5)

b5acf4f3ae45f4877603dfe073b44e8d


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science