Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Masters Theses
  5. An automated procedure for qualitative common cause failure analysis of complex systems
Details

An automated procedure for qualitative common cause failure analysis of complex systems

Date Issued
August 1978
Author(s)
James John Rooney
Advisor(s)
J. B. Fussell
Additional Advisor(s)
H. L. Dodds
E. M. Katz
P. N. Stevens
P. F. Pasqua
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/56437
Abstract

This thesis is the result of a common cause failure analysis of the Clinch River Breeder Reactor Plant (CRBRP) Shutdown Heat Removal System (SHRS). Under the assumptions made, the analysis shows that the Direct Heat Removal System (DHRS) is coupled to the Primary Heat Transport System (PHTS) during all phases of operation.

The common cause failure analysis was performed with a new automated procedure, developed as a part of this research. The results of the CRBRP SHRS common cause failure analysis indicate that the new automated procedure is a workable methodology for assessing potential common cause failures.

Major
Nuclear Engineering
File(s)
Thumbnail Image
Name

Thesis78.R665.pdf

Size

3.41 MB

Format

Adobe PDF

Checksum (MD5)

40e577c6882467b46d18de9b64cfcd0a


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science