Effect of stilling chamber velocity distortions on the test section flow angularity in a transonic wind tunnel
The accuracy of the wind tunnel simulation has been enhanced over the past several years by improvements in instrumentation systems. With a need for testing at wider ranges of model attitudes, however, there has been increased emphasis on improvements to the tunnel flow quality. An experimental investigation was conducted to assess the nature of test section disturbances resulting from velocity distortions in the stilling chamber of a transonic wind tunnel. Steady-state flow angularities were found to exist in the test section flow when velocity disturbances were introduced in the stilling chamber even though a honeycomb section was installed at the inlet of the contraction fairing. The nature of the flow angularities was found to be consistent with the orientation of the velocity disturbance.
Theoretical considerations revealed that the vorticity generated in the stilling chamber by the velocity disturbance was reoriented by the contraction fairing to produce the test section flow angularity.