Dynamic modeling and simulation of a three degree-of-freedom vibrational mass measurement system

Date Issued
May 2001
Author(s)
Sanders, Steven Ronald, 1965-
Advisor(s)
William R. Hamel
Additional Advisor(s)
Reid Kress
Gary Smith
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/55838
Abstract

This thesis presents the dynamic modeling and simulation of a three degree of freedom vibrational mass measurement system.

The system consists of two circular plates separated by four flat springs, a voice coil actuator, and a voice coil velocity sensor. The system was modeled using three equations of motion in one translational and two rotational coordinates. MatlabTM was used to determine the natural frequencies and mode shapes from the mass and stiffness matrices and to numerically solve the equations of motion. The velocity response was computed and used to determine the system transfer function at the velocity sensor. The transfer function fast Fourier transform magnitude was plotted and the peaks used as a second method to determine natural frequencies.

Simulation results revealed that central loading of the system produced one mode of vibration with primarily translational coordinate content and two modes with primarily rotational coordinate content. Experiments with various loads were performed and compared to the simulation results. The experimental data was highly repeatable. Data comparisons proved the simulation to be accurate at predicting the natural frequency associated with the translational mode but less accurate at predicting the natural frequencies associated with the rotational modes.

Experimental data from four different centrally placed loads was used to evaluate system mass measurement accuracy. The load mass was calculated from the translational mode natural frequencies. These calculated masses had a maximum error of 7.9%. System calibration would greatly improve the accuracy of the system.

Degree
Master of Science
Major
Mechanical Engineering
File(s)
Thumbnail Image
Name

Thesis2001S37.pdf

Size

34.99 MB

Format

Adobe PDF

Checksum (MD5)

b295bf1589cf35fa25d4b4b11ff787ef


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science