Pitting of austenitic stainless steel, the electrochemical basis and validity of potentiostatic measurements in acidic chloride containing media
Potentiostatic polarization measurements were performed on Type 304L stainless steel to determine the interactive effects of the variable position of a cathodic curve with a fixed anodic polarization curve. Three general types of behavior were demonstrated depending upon where and how many intersections the cathodic curve made with the typical s-shaped anodic curve for materials that exhibit active-passive behavior. The variable position of the cathodic curve was obtained by polarization of stainless steel in ferric sulphate solutions at 0.036, 0.18, and 0.36 M ferric ion concentrations. The interactions of these curves with an anodic polarization curve obtained with stainless steel tested in a solution with a pH of 0.4 and a chloride ion concentration of 1.48 M were determined analytically and experimentally. Experimental results were obtained by polarizing the stainless steel in solutions of the same pH and chloride ion content but with additions of ferric ion to the same approximate levels as were used for the cathodic polarization measurements. The interactions determined experimentally agreed qualitatively with the analytical results. The same general shapes were obtained but there was slight disagreement in terms of the predicted corrosion potentials compared to measured ones. These discrepancies were due undoubtedly in part to uncertainties in the respective ferric ion concentrations of the ferric sulphate and acidified ferric chloride solutions. In all cases these determinations were made at 10, 20, and 30°C, but the effect of tempreature was not significant.
Pitting studies for the reference Type 304L stainless steel were conducted at potentials of 0.1, 0.2, and 0.3 Volts (SHE) in 0.36 M ferric chloride solution acidified to a pH of 0.4 (chloride concentration of 1.48 M). The pit morphology and number of pits produced at the various potentials were determined by SEM and optical microscopy. Thereby, the alloy was potentiostatically corroded at potentials above and below the natural corrosion potential of the solution. It was shown that the pitting anodic oxidation process occurred not only above the corrosion potential where applied currents were anodic but also at a potential below where the applied current was cathodic. This was due to a submerged anodic partial electrochemical process that contributed to the formation of pits.
Furthermore, in these constant potential studies pitting was observed below the critical potential even as low as in the Flade region. This may be related to the protection potential concept extending as low as to the Flade potential.
A comparison was made of the pitting occurring under a freely corroding condition where the solution potential was controlled by oxidizer addition with pitting occurring under potentiostatic control in a solution without oxidizer addition. The parameter used to elevate this work was the surface appearance of metallographically prepared specimens. Accordingly, corrosive effects were greater for the freely corroding conditions as evidenced by SEM.
Thesis78H394.pdf
19.17 MB
Adobe PDF
f8ef5c1679f56ac57eab6dc08661e72e