A probe designed to measure stagnation pressure directly in supersonic flow
A probe designed to measure stagnation pressure directly in supersonic flow has been tested at Mach numbers 1.75, 2.0, 2.25, 2.5, and 3.0. The investigation included studying the effects of Mach number, total pressure, total temperature, and angle of attack on the performance of the probe. The probe decelerates a portion of the supersonic stream to a subsonic velocity partially by means of a curved compression surface and partially by a yawed body compression mechanism. A pitot tube mounted on the compression surface samples the stagnation pressure in the locally subsonic region. At optimum conditions pressure recoveries greater than 99.5 percent of the free-stream stagnation pressure were obtained.
Thesis78F544.pdf
3.99 MB
Adobe PDF
92dee685d19854e68bb4fc6bb44c0dd4