The desublimation of krypton from a noncondensable carrier gas
The purpose of this study was to obtain column concentration profiles and point buildup rates for a cold trap freezing out krypton from a nitrogen carrier gas stream and to compare those experimentally obtained profiles with profiles generated from a theoretical model. Profiles were obtained over a range of flow conditions from 0.14 to 1.06 standard cubic feet per minute, krypton feed gas concentrations varied from 5.2 to 13.5%, and cold trap operating temperatures from -281°F to -312°F. Gamma scintillation techniques using tracer amounts of krypton-85 provided the major analytical tool employed in the investigation.
Data obtained from the experiments indicate that if values for the density and thermal conductivity of the krypton frost are known, the model can accurately predict krypton loading profiles in the cold trap. The frost density and frost thermal conductivity appear to be functions of the freeze-out temperature and condensable krypton concentration. Presented in this thesis is a discussion of cold trapping theory, a description of the experimental apparatus and tests performed, and an explanation of the usefulness of the model as a design tool for engineering use.
Thesis78E337.pdf
5.69 MB
Adobe PDF
00172fb52f1c64a89fea7631939bac03