Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Masters Theses
  5. A Computational Model to Predict In Vivo Kinetics in Implanted and Non-Implanted Shoulders
Details

A Computational Model to Predict In Vivo Kinetics in Implanted and Non-Implanted Shoulders

Date Issued
August 1, 2005
Author(s)
Kubo, Matthew Brennon-Kyle
Advisor(s)
Richard D. Komistek
Additional Advisor(s)
Mohamed R. Mahfouz
William R. Hamel
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/40697
Abstract

The purpose of this study was to develop and implement a computational model designed to input in vivo kinematic and predict in vivo forces and torques for the shoulder, elbow, and wrist in normal, rotator cuff-deficient (RCD), reverse shoulder arthroplasty (RSA) and total shoulder arthroplasty (TSA) shoulder subjects. Twenty subjects, divided evenly amongst the four shoulder types, performed a box-lift activity while under fluoroscopic surveillance. Three dimensional (3D) in vivo kinematics was determined for the subjects using implant models and bone models created from CT (computed tomography) scans in a 2D-to-3D registration process. The kinematics were used as input for an inverse dynamics mathematical model, and the subject-specific kinetics were derived. Average resultant shoulder forces were 78.3N (range: 70.4N to 117N, SD: 5.213), 102N (range: 90.2N to 180.2N, SD: 12.339), 94.9N (range: 84.9N to 149N, SD: 10.02), and 92.5N (range: 87.984N to 95.370N, SD: 1.848), for normal, RCD, RSA, and TSA subjects, respectively. Average resultant shoulder torques were 23.6Nm (range: 8.32Nm to 73.7Nm, SD: 11.227), 29.6Nm (range: 22.892Nm to 71.377Nm, SD: 7.581), 27.2Nm (range: 19.961Nm to 59.352Nm, SD: 6.664), 20.3Nm (range: 11.700Nm to 31.409Nm, SD: 6.496), for normal, RCD, RSA, and TSA shoulders, respectively. This study revealed that RCD subjects exhibited a decreased ROM (range of motion) of the humeral head with respect to the glenoid, as compared to the other groups. This study also showed that subjects having a rotator cuff-deficient shoulder and/or a replaced shoulder tend to use compensatory motions to perform the task of lifting a box, and, as a result, they experience greater forces at the glenohumeral joint. Paradoxically, the RCD subjects experienced the highest joint forces and torques among the different shoulder types.

Disciplines
Engineering Science and Materials
Degree
Master of Science
Major
Engineering Science
Embargo Date
August 1, 2005
File(s)
Thumbnail Image
Name

KuboMatthewBrennon_Kyle_2005_OCRed.pdf

Size

16.2 MB

Format

Adobe PDF

Checksum (MD5)

fa49a20e37b1843d8260909be2f8c886


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science