Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Masters Theses
  5. Response of a double probe in a low density D.C. discharge with an analog circuit model comparision
Details

Response of a double probe in a low density D.C. discharge with an analog circuit model comparision

Date Issued
August 1, 1994
Author(s)
Celenza, Julia Anne
Advisor(s)
Dennis R. Keefer
Additional Advisor(s)
Rodger Crawford
George Garrison
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/32785
Abstract

The objective of this work was to obtain experimental data in a low density d.c. discharge using a double Langmuir probe system and compare these results to an analog circuit simulation. The form of the applied voltage on the probe was sinusoidal which induced sheath capacitance effects in the acquired current-voltage data. A computer simulation was used to help resolve the electron temperature, Te, plasma potential, V&subp;. and electron density, ne, from the experimental data.


Double probe measurements were performed in a low density argon d.c. discharge at a pressure of 300µm, using two electrodes having a large difference in surface areas. A specially designed circuit imposed a sinusoidal voltage on the probe, while minimizing the effect of the circuit capacitance on the results. Probe current and voltage measurements were obtained for several frequencies between 1-300Hz and an applied voltage of 120V p- p. An analog circuit simulation of the probe-plasma system was constructed using an interactive circuit design program, Design Center by MicroSim. A voltage-controlled current device was used to simulate a theoretical Langmuir probe response for each of the electrodes, while linear capacitors were used to simulate the sheath capacitance. The data taken at 1Hz was used to predict several plasma parameters for the theoretical relationships used in the simulation.

The experimental current-voltage data indicated a plasma break down had occurred at approximately 28V. Although the signal noise in the data hampered the determination of actual Langmuir probe curves, the simulation agrees with experimental data for a small range of applied voltage, below ±20V. The sheath capacitance caused a distinct phase shift in the I-V curves at the higher frequencies and, although linear capacitors provided most of the necessary phase shift, non-linear capacitors may be required for a more complete fit to the data.

Degree
Master of Science
Major
Aerospace Engineering
File(s)
Thumbnail Image
Name

Thesis94C44.pdf

Size

2.9 MB

Format

Unknown

Checksum (MD5)

e639b6e3b1c23583fa5ec9f7329d1feb


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science