Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. Investigation of Smartphone Protective Glasses for Use in Emergency Dosimetry
Details

Investigation of Smartphone Protective Glasses for Use in Emergency Dosimetry

Date Issued
August 1, 2021
Author(s)
Chandler, Joshua R
Advisor(s)
Howard L. Hall
Additional Advisor(s)
Lawrence Heilbronn
Laurence Miller
James Bogard
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/27782
Abstract

The focus of this work was to examine the thermoluminescence (TL), phototransferred thermoluminescence (PTTL), and optically stimulated luminescence (OSL) properties of the protective glasses utilized in modern smartphones and establish the ability to, after a radiation exposure, correlate the absorbed dose measured in a smartphone to that received by an individual carrying it. The primary reason for investigating the protective glasses is that their removal doesn’t completely incapacitate the phone, which is not true of methods utilizing other smartphone components, such as the display glass or surface-mount resistors (SMRs), and in the case of OSL, could potentially be used in an in-situ measurement technique. A significant background signal (BGS) contribution that could not be removed was observed during the TL and PTTL analyses, attributed to the use of UV light curing by the manufacturers, that greatly impacted the dose reconstruction process due to significant overlap with the radiation-induced signal (RIS). These results motivated the investigation of the protective glasses by means of OSL, where it was observed that the samples were not encumbered by any such BGS, making it the more encouraging luminescence technique to employ. The only drawback to utilizing an OSL technique is that the signal is susceptible to deterioration or complete erasure from light exposure; however, a recent study has shown that over 75% of smartphone users equip their devices with some form of protection. Therefore, for the devices outfitted with opaque cases or otherwise stored in the dark, utilizing an OSL technique on the protective glasses was shown to be a viable emergency dosimetry method. Previously, the majority of research focused on assessing the dose to the phone component itself, while, in reality, the dose to the individual is the most crucial to performing triage. Therefore, numerous irradiations were performed on an anthropomorphic phantom, equipped with smartphones, to calculate the conversion factors from the phone components (SMRs v and protective back glasses in this study) to the individual carrying them. The resultant factors were observed to be heavily influenced by the phone’s location and exposure geometry due to shielding from the body and exposure angle.

Subjects

Emergency Dosimetry

Retrospective Dosimet...

Thermoluminescence

Optically Stimulated ...

Disciplines
Nuclear Engineering
Degree
Doctor of Philosophy
Major
Nuclear Engineering
Embargo Date
August 15, 2024
File(s)
Thumbnail Image
Name

JRC_dissertation.pdf

Size

16.27 MB

Format

Adobe PDF

Checksum (MD5)

d134ba09060f6615f082adb42dc769fd


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science