Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. Classification of ActiGraph GT9X Accelerometer and Gyroscope Data for Characterizing Youth Physical Activity
Details

Classification of ActiGraph GT9X Accelerometer and Gyroscope Data for Characterizing Youth Physical Activity

Date Issued
May 1, 2020
Author(s)
LaMunion, Samuel Robert
Advisor(s)
Scott Crouter
Additional Advisor(s)
Eugene Fitzhugh
Joshua Weinhandl
Haileab Hilafu
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/27143
Abstract

PURPOSE: The purpose of this study is two-fold: 1) to determine if using gyroscope sensor data in place of accelerometer sensor data improves the classification of PA in youth compared to using only accelerometer sensor data, and 2) to determine if using a combined sensor approach improves classification of PA in youth compared to using either sensor independently. METHODS: These aims were evaluated two ways: 1) a within-sample cross-validation using semi-structured simulated free-living activities from 99 youth participants ages 6-18 years old, and 2) an out-of-sample validation using unstructured free-living activities from 42 youth participants ages 6-18 years old. PA data were collected using a GT9X device worn on the hip, left wrist, and right wrist. Participant’s PA behaviours were directly observed for both phases of the study to create criterion activity labels for each second of data. Four machine learning model types were developed (decision tree, random forest, logistic regression (lasso), and neural network) to classify 1) 14 individual activity classes, and 2) six activity group classes. Each model was trained using 1) accelerometer only data, 2) gyroscope only data, and 3) accelerometer + gyroscope data. RESULTS: For the within-sample cross-validation the combined sensor models achieved average classification accuracies of 61.5% for the individual activity classes and 82.0% for the activity groups, which outperformed the individual sensor models by an average of 10.4% for the individual activity classes and 5.3% for the activity groups, across all attachment sites. For the out-of-sample validation, the accelerometer only and combined sensor models classification accuracy decreased by 4.0%, 76.7% to 72.7% and 82.0% to 78.0%, respectively while the gyroscope only models maintained a classification accuracy of 76.7%. Adding transitions as a seventh activity group resulted in decreases in classification accuracy of 11.1% (within-sample) and 12.1% (out-of-sample) when compared to models excluding transitions. CONCLUSION: These studies conclude that using accelerometer and gyroscope sensor data together improves activity classification compared to using data from either single sensor alone when evaluated using semi-structured simulated free-living activity data and when using unstructured free-living activity data.

Subjects

machine learning

activity classificati...

wearable sensors

validation

physical activity

youth

Degree
Doctor of Philosophy
Major
Kinesiology and Sport Studies
Embargo Date
May 15, 2026
File(s)
Thumbnail Image
Name

utk.ir.td_12874.pdf

Size

12.59 MB

Format

Adobe PDF

Checksum (MD5)

1cf05297efd517df72e1da4d8186586a


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science