Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. The application of non-linear coherent optical processes to the measurement of number density and temperature
Details

The application of non-linear coherent optical processes to the measurement of number density and temperature

Date Issued
March 1, 1980
Author(s)
Perkins, Patrick Elliott
Advisor(s)
A. A. Mason
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/22244
Abstract
The functional form of the third-order susceptibility as it relates to Coherent Anti-Stokes Raman Scattering (CARs) and to Stimulated Raman Scattering (SRS) is developed from current literature as it applies to centrosymmetric and isotropic media (gases), including polarization effects. Mixtures of gases are also considered.

The theoretical power functions for CARS and SRS as a function of laser difference frequency are convolved with representative Gaussian laser linewidths. Spectral profiles are generated for N2 Q-branch CARS and O2 Q-branch SRS and are compared to experimental data. The effects of different number density and temperature regimes as well as laser linewidths are considered and illustrated.

The utility of CARS and SRS in the measurement of number density and temperature is determined within representative experimental regimes for two possible techniques: (1) fitting observed spectral profiles by the method of minimizing a weighted least squares functions or (2) ratioing the peak height intensity of two selected resonances including a linewidth normalization scheme.

For the method of profile fitting, the functional linewidth derivatives of the convolved power expressions and an assumed (N, T) linewidth dependence are used within the framework of multivariate non-linear regression analysis to predict realistic measurement errors from Gaussiat) shot noise, a finite signal-to-noise ratio, and linewidth uncertainties, The resonance linewidth masking due to a comparable order-of-magnitude laser linewidth is demonstrated as beneficial in regards to the error influence of detection noise as well as resonance linewidth uncertainties.

Degree
Doctor of Philosophy
Major
Physics
File(s)
Thumbnail Image
Name

Thesis80b.P474.pdf

Size

17.15 MB

Format

Unknown

Checksum (MD5)

663aa7c1463d8ca92a24759f53299fcd


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science