Time-resolved x-ray energy spectrometry as a plasma diagnostic method for the Oak Rige tokamaks

Date Issued
March 1, 1980
Author(s)
Dyer, George Richard
Advisor(s)
Owen C. Eldridge
Additional Advisor(s)
L. A. Berry
O. C. Eldridge
J. L. Dunlap
E. G. Harris
R. L. Becker
E. J. Kennedy
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/22157
Abstract
A method for measuring electron temperature (Te) and estimating effective ionic charge (Zeff) of a tokamak plasma by x-ray energy spectrometry is described. With a ten-millisecond time resolution, the technique defines values of Te and Zeff throughout the duration of single tokamak discharges.

A discussion of the x-ray emission spectrum from a tokamak plasma is presented, and the complicating effects of plasma-detector geometry, plasma temperature and density profiles, and impurity radiation are analyzed. The necessary data collection system is described, and the consequences of finite energy resolution, pulse pileup, and other deleterious effects are investigated. Results of these considerations are combined in a procedure to calculate Te and Zeff from x-ray energy data and plasma density information, and to estimate the accuracy and reliability of the derived values.

The computational procedure is applied to five different classes of tokamak discharges and the results are compared with Te. and Zeff values independently derived through a Thomson-scattering diagnostic. These comparisons show that, in general, agreement between the x-ray diagnostic and accepted techniques is good, and demonstrate the advantages of a time-resolved measurement capable of spanning an entire discharge. Where discrepancies op exist between x-ray and Thomson-scattering results, there is other evidence that the basic physics of those particular c discharges is not understood. It is concluded that the x-ray technique provides useful and unique on-line diagnostic, yielding Te and Zeff determinations good agreement with other measurements for well-behaved plasmas, and providing additional information to aid in t understanding anomalous ones.

Degree
Doctor of Philosophy
Major
Physics
File(s)
Thumbnail Image
Name

Thesis80b.D947.pdf

Size

7.14 MB

Format

Unknown

Checksum (MD5)

4bff06127af04cd92d40236cc092195b


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science