Abstract

The purposes of this study were to investigate the kinematics of two ankle brace testing protocols. They were drop landing on a slanted surface and the inversion drop test. Difference in kinematics and ground reaction forces of drop landing wearing an ankle brace on flat and lateral slant surfaces were also investigated. Eleven healthy subjects performed five trials in each of six dynamic movement conditions. They were an ankle inversion drop test on the inversion platform, drop landing from 0.45 m onto slant surface, and drop landing from 0.45 m onto flat surface with and without an ankle brace. A 7-camera motion analysis system was used to obtain the threedimensional kinematics. In addition, a force platform was used to measure the ground reaction forces (GRF) during drop landing. A 2 × 2 (brace × movement) repeated measures ANOVA was used to evaluate selected variables for inversion drop test and landing on slant surface (p < 0.05). In addition, the differences between landing on the flat and slant surfaces were examined using a 2 × 2 (brace × surface) repeated measures ANOVA. The results showed that the slant surface landing resulted in significantly earlier maximum inversion angle occurrence. Significantly higher maximum eversion and inversion velocities were also found in the slant surface landing compared to the inversion drop. In the comparison of landing on the slant surface and flat surfaces, the results showed that slant surface landing led to smaller 1stand 2ndpeak vertical and horizontal GRFs, greater maximum inversion and its range of motion (ROM), and smaller dorsiflexion ROM. The results suggest that the slant surface landing simulate ankle sprain mechanism better than the inversion drop test. Subjects adopted a softer landing strategy when landing onto the flat surface and a stiffer strategy when landing onto the slanted surface.

Disciplines
Rehabilitation and Therapy
Degree
Master of Science
Major
Exercise Science
Embargo Date
December 1, 2011
File(s)
Thumbnail Image
Name

ChenQingjian.pdf

Size

457.16 KB

Format

Adobe PDF

Checksum (MD5)

840e43c76c96875382ca52d98a286ce2


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science