  5. Neutron Imaging of Lithium Inside a High-Temperature Heat Pipe
Details

Neutron Imaging of Lithium Inside a High-Temperature Heat Pipe

Date Issued
May 1, 2013
Author(s)
Kirchoff, Eric Henry  
Advisor(s)
Kenneth D. Kihm
Additional Advisor(s)
Rao V. Arimilli
Hassina Z. Bilheux
Ahmet Turhan
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/37517
Abstract

Neutron imaging of a high-temperature Mo-Li [molybdenum-lithium] heat pipe has been performed to assess Li flow visualization. The high neutron attenuation cross section of Li allows for imaging inside the heat pipe shell structure, which has a lower value of neutron attenuation, making neutron radiography an ideal choice for characterizing Li movement.


The gravity assisted, cylindrical heat pipe was heated to 903oC [degree] using a wire resistance Mo heater operating under vacuum. This Mo-Li heat pipe is 35 cm long with a square internal geometry 2.2 cm per side, utilizing small corner radii as the wicking structure for Li return. The heat pipe is evacuated and back filled with 10 g of Li and has an estimated operational temperature of 900oC. The neutron imaging prototype facility on the CG-1D beamline at Oak Ridge National Laboratory was used to capture 30 s exposures of heat pipe operations from ambient conditions through startup to steady-state and subsequently through two large power fluctuations. Tomographic imaging of the heat pipe was performed using 180 s exposures at 1.5o increments with the heat pipe at ambient conditions.

Time lapse reconstruction of the neutron radiography shows a change in the bulk Li level and the meniscus concavity. A change of 9 mm is measured from ambient conditions to steady-state operation. This is a result of Li density changes as well as Li surface tension changes. As the temperature increases, Li held at the top of the pipe through capillary forces flows towards the evaporator increasing the bulk Li level. A decrease in the meniscus concavity confirms this. Dynamic movement is seen on one side of the pipe during both power fluctuations. Tomographic reconstruction shows Li held in the corner channels above the bulk Li level.

Subsequent work has been performed to develop a new test platform to house future neutron radiography testing. This new platform will increase efficiency on the neutron beamline by decreasing heat pipe startup time. It utilizes an induction heating system to achieve surface heating of the pipe and can be adapted to different heat pipes and orientations.

Subjects

Neutron Radiography

Heat Pipe

Neutron Tomography

Liquid Metal

Lithium

Disciplines
Other Mechanical Engineering
Degree
Master of Science
Major
Mechanical Engineering
Embargo Date
January 1, 2011
File(s)
Thumbnail Image
Name

2013_04_09__Kirchoff__Thesis_Submission.pdf

Size

2.31 MB

Format

Adobe PDF

Checksum (MD5)

d21a128654ef2c54e9bbf108ce5b60ee


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science