Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. Development of a Portable, Tileable, Dual-Particle Radiography System
Details

Development of a Portable, Tileable, Dual-Particle Radiography System

Date Issued
December 1, 2023
Author(s)
Young, Christian Xavier  
Advisor(s)
Jason P. Hayward
Additional Advisor(s)
Michael J. Liesenfelt, Jeff R. Preston, Nicole McFarlane, Michael P. Cooper
Abstract

A scalable, portable, multi-particle neutron radiography device has been developed using commercial-off-the-shelf-parts. The IDEAS ROSSPAD readout module was selected for use in developing the radiography panel due to its single-wire Power-over-Ethernet (PoE) connectivity and its tileable form factor. Each ROSSPAD detector is paired with an 8 by 8 array of 6-mm-pitch Sensl J-Series silicon photomultipliers (SiPMs). With both single and multi-ROSSPAD testing, a detection package consisting of a 3-mm-thick sheet of EJ-200 plastic scintillator and a 3-mm-thick sheet of acrylic light spreader was coupled to the SiPM board face. After both quality assurance of the detector packages and the calibration of the raw data from the ROSSPADs, sub-SiPM spatial resolution was achieved. For the single- ROSSPAD setup, modulation transfer functions (MTFs) showed spatial resolutions of 2.32 line pairs per centimeter at 10% MTF for gamma rays and 3.35 line pairs per centimeter at 10% MTF for neutrons. The multi-ROSSPAD setups performed similarly with gammas at 2.09 line pairs per centimeter at 10% MTF, while the neutron images lost some spatial resolution with 10% MTF values ranging from 1.30 to 1.46 line pairs per centimeter. Based on the physical characteristics of the board, the raw board spatial resolution sits at 0.833 line pairs per centimeter, meaning all of the methods developed could resolve an object at a sub-SiPM pitch spatial resolution. Additionally, changes to the cutoff values for the full-panel radiography system showed little change to the spatial resolution of the full-panel images, suggesting that the loss is spatial resolution is external to the data collection outside of the number of events recorded. Overall, this research resulted in the development of a state-of-the-art scalable neutron radiography system.

Subjects

neutron imaging

photon imaging

radiography

nondestructive evalua...

Disciplines
Nuclear Engineering
Degree
Doctor of Philosophy
Major
Nuclear Engineering
File(s)
Thumbnail Image
Name

Thesis_final_v2.pdf

Size

40.01 MB

Format

Adobe PDF

Checksum (MD5)

e612b79457b088943795c940a3cf30eb

Learn more about how TRACE supports reserach impact and open access here.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Contact
  • Libraries at University of Tennessee, Knoxville
Repository logo COAR Notify