Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Masters Theses
  5. Novel Approaches for the Efficient Sampling and Detection of Listeria monocytogenes and Brochothrix thermosphacta on Food Contact Surfaces
Details

Novel Approaches for the Efficient Sampling and Detection of Listeria monocytogenes and Brochothrix thermosphacta on Food Contact Surfaces

Date Issued
December 1, 2010
Author(s)
Clemons, Jessica Anne  
Advisor(s)
Dr. David Golden
Additional Advisor(s)
Arnold Saxton
Doris D'Souza
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/44288
Abstract

The primary step in the microbiological assessment of highly dynamic and complex food processing conditions is environmental sampling. The objectives of this study were to: (1) compare the efficacy of four sampling devices including Microbial-Vac system (MV), cellulose sponge (SP), polyester swab (SW) and composite tissue (CT), for the recovery of Listeria monocytogenes and Brochothrix thermosphacta on five surfaces and (2) to determine if there was a significant difference between the recovery of low (10 CFU/900cm2) and high (100 CFU/900cm2) L. monocytogenes inoculum levels using the sampling devices in a simulated food processing environment. Surfaces used for this study were stainless steel (SS), polyethylene cutting board (CB), polyurethane conveyor belt (PB), open hinge flat top conveyor belt (FT) and mesh conveyor belt (MB). Food contact surfaces were inoculated with L. monocytogenes to obtain a final cell population of 10 (low) or 100 (high) CFU/900 cm2. An average cell density of 10,000 CFU/25 cm2 was used for inoculating B. thermosphacta on each of the surfaces. Inoculated surfaces were dried and held for two hours at 4˚C then sampled and processed for detection. Because L. monocytogenes is a "zero tolerance" pathogen in ready-to-eat foods, the qualitative analysis included an enrichment step to detect presence/absence in the sample. In comparison, B. thermosphacta was directly plated in order to quantify the recovery capability of each device. Results indicated for recovery of 100 CFU/900 cm2 L. monocytogenes, there was no difference among devices on SS, CB or PB surfaces (p>0.05). However, a significant difference was detected at 10 CFU/900 cm2 on SS between MV and CT, 62.97 and 17.34%, respectively (p=0.0086). Results for FT indicated MV was superior over SP and SW (p=0.0004) for detection of high and low L. monocytogenes. There was no difference for the quantitative recovery of B. thermosphacta on PB and SS; however, there was a difference (p=0.0371) among devices on CB indicating MV was superior over SP and CT. The swab recovered 3.25 log CFU/25cm2 from flat top belts and was significantly lower (p=0.0259) than MV and SP devices, 4.29 and 4.12 log CFU/25cm2, respectively.

Subjects

surface sampling

environmental samplin...

detection

swab

sponge

microbial-vac

Disciplines
Food Microbiology
Food Science
Degree
Master of Science
Major
Food Science and Technology
Embargo Date
December 1, 2011
File(s)
Thumbnail Image
Name

ClemonsJessica_December2010thesis.pdf

Size

1.51 MB

Format

Adobe PDF

Checksum (MD5)

b84ff811794f3ed464d68dc87873c078


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science